APC AP7922B power distribution unit (PDU) 16 AC outlet(s) 2U Black

Manufacturer: APC | Model: AP7922B | Product ID: 9981 | Warranty: 2 years repair or replace
£1257.07 (inc. VAT)
3 in stock
100% Money Back Guarantee - Risk Free

Product Technical Specification

Design
PDU typesMetered,Switched
TypeSingle-phase
Rack capacity2U
MountingHorizontal
Product colourBlack
Ports & interfaces
AC outlets quantity16
Power plugIEC309
AC outlet typesC13 coupler
Features
Cable length3.05
CertificationCE, EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, VDE, REACH
Management features
MonitoringCurrent,Power,Voltage
Outlet controlLock-out,Recycle,Turn off,Turn on
Power
Nominal input voltage200-230
AC input frequency50 - 60
Maximum current32
Nominal output voltage230
Load capacity7360
Maximum input current per phase32
Maximum total current draw per phase32
Maximum power7360
Weight & dimensions
Dimensions (WxDxH)445 x 114 x 89
Weight4500
Packaging data
Package dimensions (WxDxH)508 x 368 x 140
Package weight6550
Packaging content
Packaging content
Operational conditions
Operating temperature (T-T)0 - 45
Storage temperature (T-T)-25 - 65
Operating relative humidity (H-H)0 - 95
Storage relative humidity (H-H)0 - 95
Operating altitude0 - 3000
Non-operating altitude0 - 15000
Technical details
Sustainability certificatesRoHS

Delivery Options

Economy Delivery
FREE
Economy Delivery

Economy Delivery (UK)

Estimated delivery date: Wed 26th Aug 2026 to Sat 29th Aug 2026
Business Express
£6.95
Business Express

Business Express

Estimated delivery date: Tue 25th Aug 2026 to Thu 27th Aug 2026
View all Delivery Options & International Rates
Availability

Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network

Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)

Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Network Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Local Current Monitoring Display
The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)

Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)

Marketing Features

Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

Remote Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Local Current Monitoring Display
The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.

Agility

Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

Wide range of input and output connections
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.

Rack-Mountable
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
Design
PDU typesMetered,Switched
TypeSingle-phase
Rack capacity2U
MountingHorizontal
Product colourBlack
Ports & interfaces
AC outlets quantity16
Power plugIEC309
AC outlet typesC13 coupler
Features
Cable length3.05
CertificationCE, EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, VDE, REACH
Management features
MonitoringCurrent,Power,Voltage
Outlet controlLock-out,Recycle,Turn off,Turn on
Power
Nominal input voltage200-230
AC input frequency50 - 60
Maximum current32
Nominal output voltage230
Load capacity7360
Maximum input current per phase32
Maximum total current draw per phase32
Maximum power7360
Weight & dimensions
Dimensions (WxDxH)445 x 114 x 89
Weight4500
Packaging data
Package dimensions (WxDxH)508 x 368 x 140
Package weight6550
Packaging content
Packaging content
Operational conditions
Operating temperature (T-T)0 - 45
Storage temperature (T-T)-25 - 65
Operating relative humidity (H-H)0 - 95
Storage relative humidity (H-H)0 - 95
Operating altitude0 - 3000
Non-operating altitude0 - 15000
Technical details
Sustainability certificatesRoHS

Based on 0 reviews

0

overall

Add a review

Buykingston order despatch times:

We will despatch your order the very same day if we receive cleared payment by 12:00 pm Mon-Fri.

These delivery estimates apply when you order up to 12:00 pm Mon-Fri (excluding public holidays).

We charge a one off delivery cost as outlined below regardless of how many items you order or the weight of your order.

Estimated delivery times are provided to us by the respective delivery companies. We pass this information onto you, the customer.

Despatch times do not apply to UK public holidays.

Estimated delivery times are taken from the next available working day available for delivery. For example if an order was despatched on a working Wednesday by 3pm, the first available working day for delivery would be Thursday provided you placed your order by 3pm on the Wednesday. If the next available weekday is a UK bank holiday/public holiday then your order will be despatched on the next available working day.

Our warehouse reserves the right to upgrade the delivery method you select on your order.

Our available delivery options*

Contact us for a shipping quote.

*All delivery times are estimated unless stated.

Product Returns Note

Buykingston offers a simple, hassle-free returns policy. If for whatever reason you are not happy with the item purchased, you can return it to us within 14 days of receipt for a refund. This applies to items purchased direct through Buykingston only.

Our 14 Day Returns Money Back Guarantee:
For items returned in resaleable condition, with all original packaging. If an item has been opened for inspection but shows signs of use beyond that, a deduction may apply to reflect the reduced value — see our full Terms & Conditions (Section 12) for details.

Some items are excluded from our money-back guarantee unless they have developed a fault. These include:

- Headphones
- Earphones
- Custom made and designed products, such as flash memory products with custom logos on them, e.g. USB flash drives and memory cards with your own logo

Returns FAQs

What is your returns criteria?
14 days from date of receipt, or expected date of receipt on non-tracked items.

How do I go about returning my order?
Please contact us via our contact page with your order number. We will provide you with an RMA number and return instructions, including your return deadline and whether a freepost label applies to your order.

Do I need to contact you before returning my order?
Yes, to obtain an RMA number before sending anything back.

Does my item have to include its original packaging?
Yes, to qualify for our 14 day money-back guarantee. For faulty items, we understand you may no longer have the original packaging.

Who pays for return postage?
If your item is faulty, damaged, or not as described, we cover reasonable return postage, or provide a freepost label where available. If you are returning an item for another reason (including simply changing your mind), you are responsible for return postage unless we have expressly confirmed a freepost label in your RMA email — we recommend using a tracked and insured service for items of significant value.

Who deals with the warranty on a faulty item?
We will. In some circumstances we may ask you to contact the manufacturer directly for assistance.

Please ensure you have read and comply in full with Sections 11–13 of our Terms & Conditions.